incinerator design

What Are The Types of Waste Incinerated?

​

HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan. Mobile: +86-13813931455(WhatsApp) Website: www.hiclover.com Email: sales@hiclover.com Email: hicloversales@gmail.com

Medical waste

bandage/injection syringe/ drop bottle, expired drugs, infectious internal organ, napkin, diaper, masks, gloves, general hazardous waste, laboratories waste, general bio waste in hospitals, medical center, clinics, etc.

 

 

Household waste

bottles, fruit peel,  kitchen garbage, papers, rags, leftovers, trees, leaves, lowers, roots/etc

 

Animal waste

dead animal , animal cremation and body and pets carcasses: Eg. dog, cat, chicken, duck, fish, birds, cattle, etc

 

Industrial waste municipal and general wastes

the solid waste produced in industrial area, eg. rubber, plastic, fiber, paper, leathers, wood, glass, etc

 

Other Waste Types

Chemical waste, dangerous waste, liquid waste, slugs waste, oil wastes and such waste need special types of incinerators 


Items/Model

YD-200

YD-300

YD-500

YD-600

Burning Rate (kgs/Hour)

200 kgs/Hr.

300 kgs/Hr.

500 kgs/Hr.

600 kgs/Hr.

Feed Capacity (kgs)

400 kgs

500 kgs

800 kgs

1100 kgs

Equipment Weight

7600 kgs

8300 kgs

13000 kgs

16500 kgs

Primary Chamber (Liters)

2000

2400

4000

5500

Secondary Chamber (Liters)

500

1200

1500

1500

External Dimensions (cm)

270 x 185 x 380

260x220x420

320x220x460

360 x 220 x 475

Internal Dimensions (cm)

180 x 115 x 96

220x110x100

257x147x108

300 x 147 x 125

Oil Tank(Liters)

300

500

500

500

Door Opening (cm)

59 x 81

90 x 110

108 x 128

108 x 128

Chimney (M)

10

10

14

14

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

Secondary Chamber

YES

YES

YES

YES

Mix-Combustion Chamber

YES

YES

YES

YES

Smoke Filter Chamber

YES

YES

YES

YES

Combustion Fuel

Oil/Gas

Oil/Gas

Oil/Gas

Oil/Gas

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Temperature Monitoring

YES

YES

YES

YES

1st. Chmaber Temperature

800℃-1000℃

800℃-1000℃

800℃-1000℃

800℃-1000℃

2nd. Chmaber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

What Are The Types of Waste Incinerated?

​

HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan. Mobile: +86-13813931455(WhatsApp) Website: www.hiclover.com Email: sales@hiclover.com Email: hicloversales@gmail.com

Medical waste

bandage/injection syringe/ drop bottle, expired drugs, infectious internal organ, napkin, diaper, masks, gloves, general hazardous waste, laboratories waste, general bio waste in hospitals, medical center, clinics, etc.

 

 

Household waste

bottles, fruit peel,  kitchen garbage, papers, rags, leftovers, trees, leaves, lowers, roots/etc

 

Animal waste

dead animal , animal cremation and body and pets carcasses: Eg. dog, cat, chicken, duck, fish, birds, cattle, etc

 

Industrial waste municipal and general wastes

the solid waste produced in industrial area, eg. rubber, plastic, fiber, paper, leathers, wood, glass, etc

 

Other Waste Types

Chemical waste, dangerous waste, liquid waste, slugs waste, oil wastes and such waste need special types of incinerators 


Items/Model

YD-200

YD-300

YD-500

YD-600

Burning Rate (kgs/Hour)

200 kgs/Hr.

300 kgs/Hr.

500 kgs/Hr.

600 kgs/Hr.

Feed Capacity (kgs)

400 kgs

500 kgs

800 kgs

1100 kgs

Equipment Weight

7600 kgs

8300 kgs

13000 kgs

16500 kgs

Primary Chamber (Liters)

2000

2400

4000

5500

Secondary Chamber (Liters)

500

1200

1500

1500

External Dimensions (cm)

270 x 185 x 380

260x220x420

320x220x460

360 x 220 x 475

Internal Dimensions (cm)

180 x 115 x 96

220x110x100

257x147x108

300 x 147 x 125

Oil Tank(Liters)

300

500

500

500

Door Opening (cm)

59 x 81

90 x 110

108 x 128

108 x 128

Chimney (M)

10

10

14

14

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

Secondary Chamber

YES

YES

YES

YES

Mix-Combustion Chamber

YES

YES

YES

YES

Smoke Filter Chamber

YES

YES

YES

YES

Combustion Fuel

Oil/Gas

Oil/Gas

Oil/Gas

Oil/Gas

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Temperature Monitoring

YES

YES

YES

YES

1st. Chmaber Temperature

800℃-1000℃

800℃-1000℃

800℃-1000℃

800℃-1000℃

2nd. Chmaber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

HICLOVER