Specifications for Double Chamber Incinerator:
Primary Combustion
HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan. Mobile: +86-13813931455(WhatsApp) Website: www.hiclover.com Email: sales@hiclover.com Email: hicloversales@gmail.com
・ The primary combustion chamber shall be accepted as the primary combustion zone.
・ The minimum combustion temperature of the primary chamber shall not be less than 800 degrees c
Secondary Combustion
・ The residence time in the secondary chamber shall not be less than 2 seconds
・ The gas temperature as measured against the inside wall in the secondary chamber ,not in the flame zone shall not be less than as indicated in Lot 1-7
・ Both the primary and secondary temperatures shall be maintained until all the waste has been completely combusted
Chimney
・ The chimney shall have a minimum height of 4 metres above ground level
・ The minimum exit velocity of the emissions shall not be less than 10metres/second
Temperature Warnings
・ An audible and/or visible alarm to warn the operator when the secondary temperature drops to below the required temperature
General
・ Control box can be detached and mounted on separate stand of atleast 1.5metres from the incinerator at approximately 1.6 metre height
・ CE compliant or equivalent for incinerators of this size and model
・ Drawings and photos for the offered lots
・ 1 year spare parts,fuel tanks and 10metre hose to come standard with every incinerator
Specifications for Mobile Incinerator Units
Trailer mounted mobile incinerator units suitable for the following applications
・ Medical waste
・ Domestic waste
・ Industrial waste
・ Animal cadavers