Tamaño: 940 x860x2700 milímetro Material: PILA DE ACERO INOXIDABLE, REVESTIMIENTO DE HORMIGÓN REFRACTARIO MATERIAL DE AISLAMIENTO ESPECIAL Con quemador: 15 C 20 KW Temperatura: CÁMARA PRIMARIA = 800 ° C Y CÁMARA SECUNDARIA = 850 – 1200 ° C Generación de calor suficiente para una combustión segura y completa 600-800 ° C en la primera […]
Supply, Installation and Commissioning of DIESEL FIRED INCINERATORS Medical Waste Incinerator, 100 to 120 Kg/hr Application   For incineration, general and pathological Capacity    100 C 120 kg/h burn rate Type Two  combustion chambers type; primary  and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unit Operating time                Minimum 8 hours daily Operating temperature     From 850 0C to 1200 0C, Automatic controlled Residual Ash                    5 to 10% Construction Constructed from heavy duty mild or aluminized  steel Or equal and approved equivalent Insulation material            Refractory material lining similar or equal to calcium  Silicate and hot face combination of heavy duty brickwork Internal Construction        Fixed hearth type complete with gratings, concave bottom and charging door, lined with refractory material Charging Door                   Suitable for manual loading of wastes and with smooth  Dear seal equivalent of Ceramic seals with hinges. Door Lock                          Automatic, Electric type Ash removal door    Provided, for removing resultant bottom ash leftovers                              from the Primary chamber Gratings    Provided Loading Manual loading of waste Primary Burner                        Fully automatic, with fuel, temperature and speed  controls with ignition system  flame detector                                                         Air fan Complete with safety features, flame failure                                                                    Diesel fired fuel injector type                                                Flange mounted Blower   Provided.  3 phase for supplying excess combustion air through the distribution system with speed control system Temperature Minimum exit 850 0C Observation port To be provided with protective glass type      3.3    Secondary chamber
Supply, Installation and Commissioning of DIESEL FIRED INCINERATORS Medical Waste Incinerator, 100 to 120 Kg/hr Application   For incineration, general and pathological Capacity    100 C 120 kg/h burn rate Type Two  combustion chambers type; primary  and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unit Operating time                Minimum 8 hours daily Operating temperature     From 850 0C to 1200 0C, Automatic controlled Residual Ash                    5 to 10% Construction Constructed from heavy duty mild or aluminized  steel Or equal and approved equivalent Insulation material            Refractory material lining similar or equal to calcium  Silicate and hot face combination of heavy duty brickwork Internal Construction        Fixed hearth type complete with gratings, concave bottom and charging door, lined with refractory material Charging Door                   Suitable for manual loading of wastes and with smooth  Dear seal equivalent of Ceramic seals with hinges. Door Lock                          Automatic, Electric type Ash removal door    Provided, for removing resultant bottom ash leftovers                              from the Primary chamber Gratings    Provided Loading Manual loading of waste Primary Burner                        Fully automatic, with fuel, temperature and speed  controls with ignition system  flame detector                                                         Air fan Complete with safety features, flame failure                                                                    Diesel fired fuel injector type                                                Flange mounted Blower   Provided.  3 phase for supplying excess combustion air through the distribution system with speed control system Temperature Minimum exit 850 0C Observation port To be provided with protective glass type      3.3    Secondary chamber
Medical Waste Incinerator, 50 to 60 Kg/hr Support Health Sector Support Project Point of Installation (Hospitals) Moi Voi, Makindu, Maragua, Eldama Ravine and Isiolo District Hospitals 1.    General Description Supply, delivery, installation and commissioning of a medical waste incinerator suitable for disposal of Medical, General and Pathological waste in a safe and clean environment.  The unit shall consist of two chambers and operate on the principal of controlled air and temperature. The unit shall consist a particulate remover (scrubbers) as stipulated in waste management regulations, 2006 (Legal notice NO. 121 of 29th September, 2006).  The Unit shall be fully automatic and controlled by an automatic electronic controlled system except loading system which shall be manual.  The unit shall be capable of incinerating between 50 to 60 kg of solid medical waste per hour.  It shall be constructed from mild or aluminized steel lined with refractory material. Main unit Application For incineration, general and pathological Capacity   50 C 60 kg/h burn rate Type Two  combustion chambers type; primary  and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unit Operating time                Minimum 8 hours daily Operating temperature     From 850 0C to 1200 0C, Automatic controlled Residual Ash                    5 to 10%     3.2     Primary Chamber Construction Constructed from heavy duty mild or aluminized  steel Or equal and approved equivalent Insulation material            Refractory material lining similar or equal to calcium  Silicate and hot face combination of heavy duty brickwork Internal Construction        Fixed hearth type complete with gratings, concave bottom and charging door, lined with refractory material Charging Door                   Suitable for manual loading of wastes and with smooth  Dear seal equivalent of Ceramic seals with hinges. Door Lock                          Automatic, Electric type Ash removal door    Provided, for removing resultant bottom ash leftovers                              from the Primary chamber Gratings   Provided Loading Manual loading of waste Primary Burner                        Fully automatic, with fuel, temperature and speed controls with ignition system, flame detector, Air fan complete with safety features, flame failure,  Diesel fired fuel injector type and Flange mounted                                                                                                     Blower Provided. For supplying excess combustion air through the distribution system with speed control system Temperature Minimum exit 850 0C Observation port To be provided with protective glass type Construction   Constructed from heavy duty mild or aluminized steel or equal and approved equivalent Insulation Refractory material lining Combustion Temperatures        Above 850 0C, controlled electronically […]
Medical Waste Incinerator, 50 to 60 Kg/hr Support Health Sector Support Project Point of Installation (Hospitals) Moi Voi, Makindu, Maragua, Eldama Ravine and Isiolo District Hospitals 1.    General Description Supply, delivery, installation and commissioning of a medical waste incinerator suitable for disposal of Medical, General and Pathological waste in a safe and clean environment.  The unit shall consist of two chambers and operate on the principal of controlled air and temperature. The unit shall consist a particulate remover (scrubbers) as stipulated in waste management regulations, 2006 (Legal notice NO. 121 of 29th September, 2006).  The Unit shall be fully automatic and controlled by an automatic electronic controlled system except loading system which shall be manual.  The unit shall be capable of incinerating between 50 to 60 kg of solid medical waste per hour.  It shall be constructed from mild or aluminized steel lined with refractory material. Main unit Application For incineration, general and pathological Capacity   50 C 60 kg/h burn rate Type Two  combustion chambers type; primary  and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unit Operating time                Minimum 8 hours daily Operating temperature     From 850 0C to 1200 0C, Automatic controlled Residual Ash                    5 to 10%     3.2     Primary Chamber Construction Constructed from heavy duty mild or aluminized  steel Or equal and approved equivalent Insulation material            Refractory material lining similar or equal to calcium  Silicate and hot face combination of heavy duty brickwork Internal Construction        Fixed hearth type complete with gratings, concave bottom and charging door, lined with refractory material Charging Door                   Suitable for manual loading of wastes and with smooth  Dear seal equivalent of Ceramic seals with hinges. Door Lock                          Automatic, Electric type Ash removal door    Provided, for removing resultant bottom ash leftovers                              from the Primary chamber Gratings   Provided Loading Manual loading of waste Primary Burner                        Fully automatic, with fuel, temperature and speed controls with ignition system, flame detector, Air fan complete with safety features, flame failure,  Diesel fired fuel injector type and Flange mounted                                                                                                     Blower Provided. For supplying excess combustion air through the distribution system with speed control system Temperature Minimum exit 850 0C Observation port To be provided with protective glass type Construction   Constructed from heavy duty mild or aluminized steel or equal and approved equivalent Insulation Refractory material lining Combustion Temperatures        Above 850 0C, controlled electronically […]
Servicios CMC para inclinadores durante 3 años, incluidos todos los repuestos, consumibles, mano de obra calificada, herramientas y aparejos, todo completo. Según el alcance adjunto como anexo Diseño, fabricación, suministro, entrega al sitio, instalación, prueba y puesta en servicio de todos los inclinadores de pasajeros resistentes a la intemperie de acuerdo con el alcance y […]
a.) incinerator for waste. VS pet cremation equipment for animals b.) incineration to be ash and clean it. VS cremation and collect ash into pet cremation urns. c.) waste stack disorderly.VS pet in chamber individual. d.) waste material complicated. VS pet is body. e.) waste incineration is public affairs. VS pet cremation equipment is personal […]
Waste Incinerator vs pet crematory a.) incinerator for waste. VS cremator for animalsanimal-cremation b.) incineration to be ash and clean it. VS cremation and collect ash into pet cremation urns.pet-cremation-urns c.) waste stack disorderly.VS pet in chamber individual. d.) waste material complicated. VS pet is body. e.) waste incineration is public affairs. VS pet cremation […]
Услуги CMC для инклинаторов на 3 года, включая все запасные части, расходные материалы, квалифицированную рабочую силу, инструменты и снасти. Согласно Объему, приложенному в Приложении Проектирование, производство, поставка, доставка на объект, установка, тестирование и ввод в эксплуатацию всепогодных пассажирских инклинаторов в соответствии с Объемом и техническими условиями, указанными в Приложении. Инсинератор Spesifikasi 100кг / варенье Описание […]