Tag: waste incinerators

Capacity    Not less than 500Kg/hr. Operation    24hr-7days/week continuous operation. Combustion chamber    2 combustion chamber. Temp.    First combustion chamber 800-1000 C. Secandry combustion chamber 1000-1200 C, with the possibility to be upgraded to 1400 C. Combustion Efficiency    99.99% Retention time    Of the flow gases not less than 2 Sec in the hot portion. Excess Oxygen concentration   […]
1) Policy – – – – Incinerator: It is developed to sanitize medical waste, lower its amount, and make its parts unrecognizable all in one completely confined as well as automated system. 2) Waste Disposal Plan a)Classification The contaminated waste is filled up right into the leading stainless-steel chamber where a tough shredder reduces the waste into […]
The incinerator plant shall include a control board for its treatment. On the control panel we will have an aesthetic display of the chamber temperature level levels. This aesthetic screen needs to maintain an eye and handle on the burner in addition to his performance. Capacity of destruction in weight will be 60 Kg/h. It […]
Stack size shall be in accordance with the manufacturer’s recommendations. Stacks shall be the forced-air type and   completely self-supporting and unattached to nearby structures. As a minimum, stack heights shall minimize   downwash of stack emissions due to aerodynamic influences from nearby structures and be calculated in accordance   with DoD 4715.05-G, Overseas Environmental […]
waste itself, running problems in the shed chamber (i.e. temperature degree, holding time as well as likewise disturbance) and also motorist capability. Waste having chlorinated materials (i.e. chlorinated solvents and plastics, PVC piping, lumber treated with pentachlorophenol or PCB-amended paint, aquatic driftwood) should be divided from different other waste as their burning will absolutely result […]
oElectro-ventilator distributing the secondary air, the regulation of the air flow being carried out by valves and following the control of the automatic cycle. Controls and regulations: Control box watertight to dust, including:   A switch circuit breaker for each engine (ventilators and burners). A timer with adjustable temporization for the regulation of each burner. […]
* Burner with gas, mono-bloc spreading helping kind with straight fire, lights as well as safety and safety of digital ignition, long-term ventilation, electro-magnetic sluice gate of plan and dividing shutoff. * An additional shot of air to ensure excellent oxygen material. 19. A control box guaranteeing the overall cycle of burning. 20. Fan: * […]
1. Capability of damage in weight: 60 Kg/h. 2. It should be able to run very little less than 10 hours/day 3. This burner needs to have the ability to destroy all combustible wastes created by healthcare facilities, unique centers, research laboratories, institutes, and so forth. 4. Style Requirements: Kinds A, B, C, D, as […]
INCINERATEUR DE DECHETS HOSPITALIER health center incinerator format SPECS TECHNIQUES. Capacité harmful de 55 Kg/h jour de déchets hospitaliers avec un p?. c. i jusqu’ à 3.200 Kcal/Kg 1) Kind de déchet hospitalier 2) Pouvoir calorifique inférieur 3.200 kcal/kg 3) Humidité 20%. 4) Teneur en cendres et/ou inertes 8%. 5) Capacité harmful nominale 55 kg/h. […]
This Server Pack (Supplied As Part of the Machine) Constitutes Sufficient Parts to Maintain the Machine Adequately For A 3 Years; the Parts in the Kit Mainly Related To Diesel Fired Burners and Are As Follows;   Thermocouple Temperature Sensor -2 Burner Blast Tubes -3 Burner Diffuser Assemblies -3 0.65 Dia: Nozzles -4   There […]